Best 3TF AC Contactor 220 Volt for Home & Office
Application
3TF series AC contactor are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9-475A under AC-3 duty. It is mainly used for making/breaking electric circuit at a long distance& for frequent starting/stopping &with thermal relay to compose a magnetic motor starter. The product conforms to IEC60947-4-1 standard.
Specification
Type |
3TF- 9/12 |
3TF- 16/22 |
3TF- 32 |
3TF- 45/63 |
3TF- 75/85 |
3TF- 110/140 |
3TF- 170/205 |
3TF- 250/300 |
3TF- 400/475 |
|
Mechanical Endurance (X106) |
10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | |
Conventional thermal current(A) |
20 | 30 | 45 | 80 | 100 | 160 | 210 | 300 |
400/ 550 |
|
Rated insulation voltage(V) |
660 | 660 | 660 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated operating current(A) |
AC-3 | 9/12 | 16/22 | 32 | 45/63 | 75/85 |
110/140 |
170/ 205 |
250/ 300 |
400/ 475 |
Rated operating current(A) |
AC-4 | 3.3/4.3 | 7.7/8.5 | 15.6 | 24/28 | 34/42 | 54/68 | 75/96 | 110/125 | 150 |
Power of controllable motor(KW) AC-3 |
380V | 4/5.5 | 7.5/11 | 15 | 22/30 | 37/45 | 55/75 | 90/110 |
132/ 160 |
200/ 250 |
Power of controllable motor(KW) AC-3 |
660V | 5.5/7.5 | 11 | 23 | 39/55 | 67 | 100 | 156 | 235 | 375 |
Power of controllable motor(KW) AC-4 |
380V | 1.4/1.9 | 3.5/4 | 7.5 | 12/14 | 17/21 | 27/35 | 38/50 | 58/66 | 81 |
Power of controllable motor(KW) AC-4 |
660V | 2.4/3.3 | 6/6.6 | 13 | 20.8/24 | 29.5/36 | 46.9/60 | 66/86 | 100/114 | 140 |
Frequency of operation (I/h) |
AC-3 | 1000 | 750 | 750 |
1200/ 1000 |
1000/ 850 |
1000/ 750 |
700/ 500 |
700/ 500 |
500/ 420 |
Frequency of operation (I/h) |
AC-4 | 250 | 250 | 250 | 400/300 | 300/250 | 300/200 | 200/130 | 200/130 | 150 |
Electrical endurance (X106) |
AC-3 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
Electrical endurance (X106) |
AC-4 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Operating voltage range of coil |
(0.8-1.1) Ue |
|
|
|
|
|
|
|
|
|
Power consumption of coil |
Atracting (VA) |
10 | 10 | 12.1 | 17 | 32 | 39 | 58 | 84 | 115 |
Power consumption of coil |
Starting (VA) |
68 | 69 | 101 | 183 | 330 | 550 | 910 | 1430 | 2450 |
Rated insulation voltage of auxiliary contacts(V) |
690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Conventional thermal current of auxiliary contacts(A) |
10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated operating current of auxiliary contacts(A) |
AC15 380/220 |
6/10 | 6/10 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
Rated operating current of auxiliary contacts(A) |
DC13 220v | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 |
Rated voltage of the control coil(V) |
50HZ |
24 36 48 110 127 220 380,etc |
||||||||
Rated voltage of the control coil(V) |
60HZ | 24 110 220 440 etc |